@@ -257,6 +257,7 @@ If an AI assistant is helping with install, reinstall, bootstrap, provider setup
### Authentication and security ### Authentication and security
- Optional password auth -- off by default, zero friction for localhost - Optional password auth -- off by default, zero friction for localhost
- Enable via `HERMES_WEBUI_PASSWORD` env var or Settings panel - Enable via `HERMES_WEBUI_PASSWORD` env var or Settings panel
- Installed PWAs work best with WebUI's own password. Reverse proxies are supported, but proxy basic auth can block the service-worker update fetches an installed app needs and leave it on a blank screen after an update; see `docs/troubleshooting.md` for recovery steps.
- Optional passkeys/WebAuthn -- register from Settings -> System after signing in with a password; the login page only shows passkey sign-in after at least one passkey exists - Optional passkeys/WebAuthn -- register from Settings -> System after signing in with a password; the login page only shows passkey sign-in after at least one passkey exists
- After registering at least one passkey, Settings -> System can remove the password and keep passkey-only sign-in enabled. Password auth remains the bootstrap/recovery path until you choose to go passwordless; passkeys are same-origin and stored locally in the WebUI state directory - After registering at least one passkey, Settings -> System can remove the password and keep passkey-only sign-in enabled. Password auth remains the bootstrap/recovery path until you choose to go passwordless; passkeys are same-origin and stored locally in the WebUI state directory
- Optional native OIDC login for WebUI sessions -- configure `webui_oidc.issuer`, `client_id`, `allow_claim`, and `allow_values` in `config.yaml`, or set the matching `HERMES_WEBUI_OIDC_*` environment variables. OIDC stays disabled until all four are present, and startup prints a warning if the config is partial. - Optional native OIDC login for WebUI sessions -- configure `webui_oidc.issuer`, `client_id`, `allow_claim`, and `allow_values` in `config.yaml`, or set the matching `HERMES_WEBUI_OIDC_*` environment variables. OIDC stays disabled until all four are present, and startup prints a warning if the config is partial.
+2
View File
@@ -168,6 +168,8 @@ Docker UID/GID and mount guidance in [Docker setup guide](docker.md).
Password protection is optional for localhost-only installs. Enable it if you Password protection is optional for localhost-only installs. Enable it if you
expose WebUI outside `127.0.0.1`, behind a reverse proxy, or on a LAN. expose WebUI outside `127.0.0.1`, behind a reverse proxy, or on a LAN.
For installed PWAs, prefer WebUI's built-in password over proxy basic auth. Reverse proxies are supported, but HTTP basic-auth challenges in front of the WebUI origin can interrupt the service-worker and shell-asset fetches the installed app relies on during updates. If you keep proxy auth, scope it so same-origin `sw.js`, manifest, and shell update requests can complete.
The password is stored through the normal WebUI settings path and hashed The password is stored through the normal WebUI settings path and hashed
server-side. You can change it later from Settings. server-side. You can change it later from Settings.
+18
View File
@@ -159,6 +159,24 @@ turn in the exhausted session instead of being blocked with recovery guidance.
--- ---
## Installed PWA opens to a blank screen after an update
**Symptom.** The installed PWA or home-screen app opens to a blank screen after a WebUI update, while the same URL often works again in a normal browser tab.
**Why.** Reverse proxies are supported, but proxy basic auth can challenge the same-origin `sw.js`, manifest, or versioned `static/*` fetches the installed app needs while its service worker updates the shell.
**Diagnostic.**
1. Open the same WebUI URL in a regular browser tab and confirm whether it loads there.
2. Check reverse-proxy logs for `401` responses on `/sw.js`, `/manifest.json`, or versioned `/static/*` assets during the update.
3. Temporarily remove proxy basic auth and use WebUI's built-in password. If the blank screen stops after the next update, the proxy auth challenge was the trigger.
**Fix.** Prefer WebUI's own password for installed PWAs. If you keep proxy basic auth, configure it so the same-origin service-worker and shell update fetches can complete. If the installed shell is already blank, clear site data for the Hermes origin, then reopen or reinstall the PWA after that site-scoped cleanup.
**When to file a bug.** File a WebUI bug if the blank screen still reproduces without proxy basic auth, or after the proxy allows the same-origin service-worker and shell update fetches through.
---
## Other troubleshooting ## Other troubleshooting
This document grows over time. If a recurring failure mode isn't covered here yet, add it via PR. The format for each entry: **Symptom → Why → Diagnostic commands → Fix → When to file a bug**. This document grows over time. If a recurring failure mode isn't covered here yet, add it via PR. The format for each entry: **Symptom → Why → Diagnostic commands → Fix → When to file a bug**.